Non adhesive VARNICOMP SR is installed on press with the small bars used with calibrated papers.
How to install the VARNICOMP SR adhesive:
Clean and degrease the cylinder surface
Strip a 15-20 cm polypropilene adhesive protection liner from the back of VARNICOMP SR at the clamp side.
Apply carefully VARNICOMP SR along the clamp edge, complete the liner removal with regularity and apply pressure by hands from the center to the edges to eliminate air bubbles.
The small pressure roll, when installed, will help the process, it is advisable to mount a coating plate VARNIPLATE on the cylinder and run some cylinder revolutions. VARNICOMP SR has a soft compressible layer protecting from vibration and machine noise.
VARNICOMP SR is easily replaceable from the cylinder at the end of press life.
TYPE | UNDERBLANKET |
THICKNESS | 1.00 MM, 1.30 MM, 1.45 MM, 1.95 MM, 2.10 MM |